COMMENT
Since this is an electrode current, positive values of i depolarize the cell
and in the presence of the extracellular mechanism there will be a change
in vext since i is not a transmembrane current but a current injected
directly to the inside of the cell.
ENDCOMMENT
INDEPENDENT {t FROM 0 TO 1 WITH 1 (ms)}
NEURON {
POINT_PROCESS MyIClamp
RANGE del, dur, amp,amp2,i
ELECTRODE_CURRENT i
}
UNITS {
(nA) = (nanoamp)
}
PARAMETER {
del (ms)
dur (ms) <0,1e9>
amp (nA)
amp2 (nA)
}
ASSIGNED { i (nA) }
INITIAL {
i = amp
}
BREAKPOINT {
at_time(del)
at_time(del+dur)
if (t < del + dur && t > del) {
i = amp +amp2
}else{
i = amp
}
}