% This script experiments with sensitivity to ISI jitter with varying
% population sizes and firing rates.
clear all
jitter = [0 .001 .002 .004 .008 .016];
% population size, mean firing rate, Poisson mix coefficient, regular coefficient, burst coefficient, Poisson refractory time
cases = [ ...
500 2 1 0 0 .002; ...
500 5 1 0 0 .002; ...
500 10 1 0 0 .002; ...
500 20 1 0 0 .002; ...
500 40 1 0 0 .002; ...
500 80 1 0 0 .002; ...
500 160 1 0 0 .002; ...
500 320 1 0 0 .002; ...
500 2 1 0 0 0; ...
500 5 1 0 0 0; ...
500 10 1 0 0 0; ...
500 20 1 0 0 0; ...
500 40 1 0 0 0; ...
500 80 1 0 0 0; ...
500 160 1 0 0 0; ...
500 320 1 0 0 0; ...
250 40 1 0 0 .002; ...
750 40 1 0 0 .002; ...
1000 40 1 0 0 .002; ...
1250 40 1 0 0 .002; ...
1500 40 1 0 0 .002; ...
]
dt = .0002;
T = .3;
covT = 20; % longer simulations used for COV calculations
x = load('signals_figure4.mat');
signals = x.signals;
meanCOV = [];
meanE = [];
sdE = [];
for i = 1:size(cases,1)
params = struct('RT', cases(i,6));
% generate long firing patterns to get COV estimate
[spikes, cov] = genUncorrelated(20, covT, dt, cases(i,2), cases(i,3:5), params);
meanCOV = [meanCOV; mean(cov)]
% We have to use a 1ms intervals with large populations, to avoid running out of memory. However with
% 1ms intervals, firing rates < 10Hz, and no jitter, about one case in 10 has abnormally high error (about
% an order of magnitude greater than usual). This doesn't happen with .2ms intervals. We assume this is a
% numerical problem, and try to avoid this case.
if cases(i,1) > 600
interval = 5;
else
interval = 1;
end
for j = 1:length(jitter)
for k = 1:size(signals,1)
% generate test firing patterns
[spikes, cov] = genUncorrelated(cases(i,1), T, dt, cases(i,2), cases(i,3:5), params);
% find weights to approximate target current signal
[weights, err, t] = decode(signals(k,:), .0002, spikes, [jitter(j) 0 0], [0 0 0], [0 10], 0, 32, 5, interval);
t
meanE(i,j,k) = mean(err)
sdE(i,j,k) = std(err);
end
end
save 'data_populationSizeRate.mat'