TITLE somatic leak
COMMENT
------------------------------------------
Ragnhild Halvorsrud June 1999
Dep. of Physiology, University of Oslo
------------------------------------------
Reference:
Lyle Borg-Graham: 'Interpretations of Data and Mechanisms for HPC-Models'
in "Cerebral Cortex" vol. 12: Cortical Models.
Eds: Jones, E. G. and Ulinski, P. S.
Q10: Temperature sensitivity
T_ref: Reference temperature
T_corr: Correction factor when using other temperatures than T_ref
NB NB
The leak conductance accounts for the
somatic shunt (sharp electrode recording).
The soma specific resistance is Rm = 2.5 kOhm.
Another value must be used for dendritic membrane.
ENDCOMMENT
UNITS {
(mV) = (millivolt)
(mA) = (milliamp)
}
NEURON {
SUFFIX WMPas2
NONSPECIFIC_CURRENT i
RANGE g, eleak
}
PARAMETER {
v (mV)
g = .0004 (mho/cm2) <0,1e9>
eleak = -65 (mV)
}
ASSIGNED {
i (mA/cm2)
}
BREAKPOINT {
i = g*(v - eleak)
}