Spatial gridding and temporal accuracy in NEURON (Hines and Carnevale 2001)


A heuristic for compartmentalization based on the space constant at 100 Hz is proposed. The paper also discusses spatio/temporal accuracy and the use of CVODE.

Model Type: Neuron or other electrically excitable cell

Model Concept(s): Tutorial/Teaching; Methods

Simulation Environment: NEURON

Implementer(s): Hines, Michael [Michael.Hines at Yale.edu]

References:

Hines ML, Carnevale NT. (2001). NEURON: a tool for neuroscientists. The Neuroscientist : a review journal bringing neurobiology, neurology and psychiatry. 7 [PubMed]