Westwick DT, Pohlmeyer EA, Solla SA, Miller LE, Perrault EJ. (2005). Identification of Multiple-Input Systems with Highly Coupled Inputs: Application to EMG Prediction from Multiple Intracortical Electrodes Neural Comput. 18

See more from authors: Westwick DT · Pohlmeyer EA · Solla SA · Miller LE · Perrault EJ

References and models cited by this paper

Bienenstock E et al. (2003). A switching Kalman filter model for the motor cortical coding of hand motion 25th International IEEE-EMBS Conference.

Bussgang JJ. (1952). Crosscorrelation functions of amplitude distorted gaussian signals Mit Res Lab Elec Tech Rep. 216

Carmena JM et al. (2003). Learning to control a brain-machine interface for reaching and grasping by primates. PLoS biology. 1 [PubMed]

Chapin JK, Moxon KA, Markowitz RS, Nicolelis MA. (1999). Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex. Nature neuroscience. 2 [PubMed]

Chen S, Cowan CN, Grant PM. (1991). Orthogonal least squares learning algorithm for radial basis function networks. IEEE transactions on neural networks. 2 [PubMed]

Donoghue JP. (2002). Connecting cortex to machines: recent advances in brain interfaces. Nature neuroscience. 5 Suppl [PubMed]

Donoghue JP, Bienenstock E, Gao Y, Wu W, Black MJ. (2003). A quantitative comparison of linear and non-linear models of motor cortical activity for the encoding and decoding of arm motions 1st International IEEE-EMBS Conference on Neural Engineering.

Golub G, Van_loan C. (1989). Matrix computations (2nd ed).

Isaacs RE, Weber DJ, Schwartz AB. (2000). Work toward real-time control of a cortical neural prothesis. IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 8 [PubMed]

Kearney RE, Westwick DT. (2004). Generalized eigenvector algorithm for nonlinear system identification with non-white inputs. Ann Biomed Eng. 25

Kennedy PR, Bakay RA, Moore MM, Adams K, Goldwaithe J. (2000). Direct control of a computer from the human central nervous system. IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 8 [PubMed]

Korenberg MJ. (1988). Identifying nonlinear difference equation and functional expansion representations: the fast orthogonal algorithm. Annals of biomedical engineering. 16 [PubMed]

Lauer RT, Peckham PH, Kilgore KL, Heetderks WJ. (2000). Applications of cortical signals to neuroprosthetic control: a critical review. IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 8 [PubMed]

Maynard EM, Nordhausen CT, Normann RA. (1997). The Utah intracortical Electrode Array: a recording structure for potential brain-computer interfaces. Electroencephalography and clinical neurophysiology. 102 [PubMed]

Miller A. (1990). Subset selection in regression.

Mussa-Ivaldi FA, Miller LE. (2003). Brain-machine interfaces: computational demands and clinical needs meet basic neuroscience. Trends in neurosciences. 26 [PubMed]

Nicolelis MA et al. (2003). Chronic, multisite, multielectrode recordings in macaque monkeys. Proceedings of the National Academy of Sciences of the United States of America. 100 [PubMed]

Paninski L, Fellows MR, Hatsopoulos NG, Donoghue JP. (2004). Spatiotemporal tuning of motor cortical neurons for hand position and velocity. Journal of neurophysiology. 91 [PubMed]

Perreault EJ, Kirsch RF, Acosta AM. (1999). Multiple-input, multiple-output system identification for characterization of limb stiffness dynamics. Biological cybernetics. 80 [PubMed]

Sanchez JC et al. (2004). Ascertaining the importance of neurons to develop better brain-machine interfaces. IEEE transactions on bio-medical engineering. 51 [PubMed]

Schweighofer N, Doya K. (2003). Meta-learning in reinforcement learning. Neural networks : the official journal of the International Neural Network Society. 16 [PubMed]

Serruya MD, Hatsopoulos NG, Paninski L, Fellows MR, Donoghue JP. (2002). Instant neural control of a movement signal. Nature. 416 [PubMed]

Taylor DM, Tillery SI, Schwartz AB. (2002). Direct cortical control of 3D neuroprosthetic devices. Science (New York, N.Y.). 296 [PubMed]

Taylor DM, Tillery SI, Schwartz AB. (2003). Information conveyed through brain-control: cursor versus robot. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 11 [PubMed]

Warland DK, Reinagel P, Meister M. (1997). Decoding visual information from a population of retinal ganglion cells. Journal of neurophysiology. 78 [PubMed]

Wessberg J et al. (2000). Real-time prediction of hand trajectory by ensembles of cortical neurons in primates. Nature. 408 [PubMed]

Westwick DT, Kearney RE. (1997). Identification of physiological systems: a robust method for non-parametric impulse response estimation. Medical & biological engineering & computing. 35 [PubMed]

Williams JC, Rennaker RL, Kipke DR. (1999). Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. Brain research. Brain research protocols. 4 [PubMed]

References and models that cite this paper
This website requires cookies and limited processing of your personal data in order to function. By continuing to browse or otherwise use this site, you are agreeing to this use. See our Privacy policy and how to cite and terms of use.